AMT 300 Series Investment cast Stainless Steel Transfer pumps are designed to handle liquids and chemicals with specific gravities to 1.6. The pumps are particularly well suited to applications involving perchloroethylene (PCE) and are recommended for use with non-flammable liquids. These pumps are fitted with Viton® mechanical seal and O-ring. Self-priming to 6 Ft.

AMT Stainless Steel Transfer pumps are reliable, cost effective and low maintenance. Many are readily available “Off-the-Shelf” for fast 24 hour shipment. For use with non-flammable liquids compatible with pump component materials.
  • 300 Series Investment Cast Stainless Steel Construction
  • Viton® Mechanical Seal and O-Ring
  • Handles Liquids and Chemicals with Specific Gravities up to 1.6
  • 1" NPT Suction and Discharge Ports
  • Maximum Working Pressure 75 PSI
  • Maximum Temperature 200° F
  • Maximum Flow 66 GPM
  • Maximum Head 68 ft.
  • Self-priming to 6 ft.
  • Self-cleaning, Semi-open Impeller
  • Available with Open Drip Proof (ODP) or Totally Enclosed Fan Cooled (TEFC) Motor
  • 1/3 to 2 HP Single or Three Phase Motor
Unit of Measure
Items
Model 429A-98

4294-98
Unit Price QUOTE

Model 429A-98

4295-98
Unit Price QUOTE

Model 429A-98

4296-98
Unit Price QUOTE

Model 429A-98

4297-98
Unit Price QUOTE

Model 429A-98

4298-98
Unit Price QUOTE
Manufacturer N/A American Machine and Tool Company
Model # N/A 4294-98 N/A 4295-98 N/A 4296-98 N/A 4297-98 N/A 4298-98
Curve N/A E N/A D N/A C N/A B N/A A
Power N/A 1/3 hp N/A 1/2 hp N/A 3/4 hp N/A 1 hp N/A 1 1/2 hp
Phase N/A 1
Voltage at 60 Hz1 N/A 115/230 V
Full Load Current N/A 8/4 A N/A 10/5 A N/A 13/7 A N/A 17/9 A N/A 22/11 A
Inlet Size
N/A 1 in
Porting Position N/A 1 in
Temperature N/A 200 ºF
Max. Flow Rate N/A 66 gpm
Self-Priming N/A 6 ft
Installed Option N/A Silicon Carbide/Viton Seal and O-ring Installed (429X-300-VS) ($122.00)
Note N/A Electric supply for ALL motors must be within ±10% of nameplate voltage rating
  • 1 3-Phase models can also operate on 50 Hz (This will change Full Load Amps and Service Factor, RPM and Priming Capabilities).
^